Martha, SK and Hariprakash, B and Gaffoor, SA and Ambalavanan, S and Shukla, AK (2005) Assembly and performance of hybrid-VRLA cells and batteries. In: Journal of Power Sources, 144 (2). pp. 560-567.
|
PDF
A90.pdf Download (733Kb) |
Abstract
Several commercial-grade hybrid-VRLA and AGM-VRLA cells and batteries have been assembled and tested under varying charge-discharge rates in a temperature range between 50 and -40 degrees C. Impedance studies on hybrid-VRLA and AGM-VRLA cells have been conducted to reflect on their resistive and capacitive values. A linear relationship is found to exist between logarithmic state-of-charge values and ohmic impedance of batteries. In general, hybrid-VRLA cells and batteries perform better than their AGM-VRLA counterpart. A field-performance study conducted on AGM-VRLA and hybrid-VRLA batteries for solar-lighting application also suggests the latter to be superior.
| Item Type: | Journal Article |
|---|---|
| Additional Information: | Copyright for this article belongs to Elsevier. |
| Keywords: | VRLA batteries;Absorbent-glass-mat (AGM);Gelled electrolyte;Colloidal silica;Hybrid;Oxygen recombination |
| Department/Centre: | Division of Chemical Sciences > Solid State & Structural Chemistry Unit |
| Date Deposited: | 26 Jul 2005 |
| Last Modified: | 19 Sep 2010 04:19 |
| URI: | http://eprints.iisc.ernet.in/id/eprint/3398 |